P.V.C COMPOUND FOR WIRES & CABLES
|
Property |
Unit |
W.Type5 |
W.Type9 |
Test method |
Min. tensile strength |
kg / cm 2 |
220 |
150 |
BS-6469 |
Min. elongation at break |
% |
250 |
240 |
BS-6469 |
Cold bend temp. |
° c |
-15 |
-15+/-2 |
BS-6469 |
Temp. of resistanceTo cracking |
° c |
150 |
150+/-2 |
BS-6469 |
Density |
gm/cm 3 |
1.4 |
1.475 |
BS-2782 |
Shore hardness |
A |
91 |
80 |
ASTMD2240 |
Max. loss of mass |
mg/cm 2 |
1 |
1 |
BS-6469 |
Min. volume resistivity |
Ω, cm |
2.1x10 14 |
3.5x10 13 |
ASTMD257 |
Specifications
P.V.C COMPOUND FOR WIRES & CABLES
|
Property |
Unit |
W.TI1 |
W.TI 2 |
W.TM 1 |
Test method |
Min.
tensile strength |
kg / cm2 |
140 |
120 |
140 |
BS-6469 |
Min.
elongation at break |
% |
250 |
260 |
250 |
BS-6469 |
Cold bend temp |
°c |
-15+/ 2 |
-15+/-2 |
-15+/2 |
BS-6469 |
Temp. of resistance To cracking |
°c |
150+/-2 |
150+/-2 |
150+/-2 |
BS-6469 |
Density |
gm / cm3 |
1.49 |
1.461 |
1.49 |
BS-2782 |
Shore hardness |
A |
80+/-1 |
70+/-1 |
80+/-1 |
ASTMD2240 |
Max. loss of mass |
mg /cm2
|
1.2 |
1.5 |
1.2 |
BS-6469 |
Min. volume
resistivity |
Ω, cm |
4x1013 |
1.4x1013 |
|
ASTMD257 |
Specifications
P.V.C COMPOUND For shoes , sole & hoses
|
Grade |
|
|
Tensile strength
kg / cm 2
|
Elongation
at break% |
|
50 |
1.152 |
95 |
420 |
|
55 |
1.165 |
100 |
415 |
|
60 |
1.167 |
110 |
410 |
WSH 65 |
65 |
1.170 |
125 |
400 |
|
|
1.183 |
160 |
390 |
|
75 |
1.193 |
170 |
365 |
|
80 |
1.225 |
180 |
320 |
|
85 |
1.235 |
205 |
300 |
WSH 90 |
90 |
1.249 |
215 |
270 |
|
|
 |
 |
|